North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: Loss of Telnet Capability to 6509

  • From: Richard J. Sears
  • Date: Wed Jul 28 15:12:01 2004

Hi Robert - 

There is only a single connection to vty 2 (which I cannot clear) other
than that, there are no other connections at all.


On Wed, 28 Jul 2004 15:03:44 -0400
Robert Blayzor <[email protected]> wrote:

> 
> Richard J. Sears wrote:
> 
> > Anyone have a similar problem or know how to check or restart the telnet
> > process on the router without a reload...?
> 
> Isnt't here a maximum of VTY's that can be used at one time?  Perhaps 
> that's the problem.  From the console what does the swtich say if you do 
> a "show users" or "who" ?
> 
> If it shows users, then there are some other connections using the VTY's 
> and probably not permitting any more connections.
> 
> Try clearing the vty's if you think they are stale.
> 
> -- 
> Robert Blayzor
> INOC, LLC
> [email protected]


******************************************
Richard J. Sears
Vice President         
American Digital Network                          
----------------------------------------------------
[email protected]
http://www.adnc.com
----------------------------------------------------
858.576.4272 - Phone
858.427.2401 - Fax
INOC-DBA - 6130
----------------------------------------------------

I fly because it releases my mind 
from the tyranny of petty things . . 


"Work like you don't need the money, love like you've
never been hurt and dance like you do when nobody's
watching."