North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: 40Gbit private peer

  • From: Leigh Porter
  • Date: Thu Aug 02 15:25:24 2007



I hope they have good peering :)

Blake Pfankuch wrote:
I would be interested to see how a torrent reacts on a line like that :D

-Blake

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of
Leigh Porter
Sent: Thursday, August 02, 2007 12:36 PM
To: Peter Lothberg
Cc: [email protected]
Subject: Re: 40Gbit private peer


Hey,


BEcause you really need it ;-)

30 second input rate 77849000 bits/sec, 7236 packets/sec
30 second output rate 17464000 bits/sec, 5023 packets/sec

Very nice though, it'll be great for all the P2P.

--
Leigh



Peter Lothberg wrote:
SUnet (AS1653) and STUPI (AS1880) want to announce that we have brought up what we believe is the first private peer at 40G between two independent networks.

It speaks IPv4, IPv6 both unicast and multicast.

-Peter


------------------------------------------------------------------------
RP/0/RP0/CPU0:HFR1-F#sh int pos 0/3/0/0
POS0/3/0/0 is up, line protocol is up
Interface state transitions: 2
Hardware is Packet over SONET/SDH
Description: OC768 Private Peering to Sunet <[email protected]>
Internet address is 193.11.20.146/30
MTU 4474 bytes, BW 39813120 Kbit
reliability 255/255, txload 0/255, rxload 0/255
Encapsulation HDLC, crc 32, controller loopback not set, keepalive
set (10 sec)
  Last clearing of "show interface" counters 1d00h
  30 second input rate 77849000 bits/sec, 7236 packets/sec
  30 second output rate 17464000 bits/sec, 5023 packets/sec
     115627177 packets input, 155140727534 bytes, 0 total input drops
     0 drops for unrecognized upper-level protocol
     Received 0 runts, 0 giants, 0 throttles, 0 parity
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     78946374 packets output, 34499886901 bytes, 0 total output drops
     0 output errors, 0 underruns, 0 applique, 0 resets
     0 output buffer failures, 0 output buffers swapped out

RP/0/RP0/CPU0:HFR1-F#sh controllers soNET 0/3/0/0
Port SONET0/3/0/0:

Status: Up

Loopback: None

SECTION
  LOF = 0          LOS    = 0                            BIP(B1) = 0
LINE
  AIS = 0          RDI    = 0          FEBE = 0          BIP(B2) = 0
PATH
  AIS = 0          RDI    = 0          FEBE = 0          BIP(B3) = 0
  LOP = 0          NEWPTR = 0          PSE  = 0          NSE     = 0
  PLM = 0          TIM    = 0
Detected Alarms: None
Asserted Alarms: None
Mask for Detected->Asserted: None
Detected Alerts: None
Reported Alerts: None
Mask for Detected->Reported: None
Alarm reporting enabled for: SLOS SLOF SF_BER PLOP
Alert reporting enabled for: B1-TCA B2-TCA B3-TCA

Framing: SONET
SPE Scrambling: Enabled
C2 State: Stable C2_rx = 0x16 (22) C2_tx = 0x16 (22) / Scrambling
Derived
S1S0(tx): 0x0 S1S0(rx): 0x0 / Framing Derived

PATH TRACE BUFFER : STABLE
  Remote hostname : c1sth-re1 so-7/0/0
  Remote interface:
  Remote IP addr  :

APS
No APS Group Configured
  Protect  Channel 0   DISABLED
  Rx(K1/K2) : 0x00/0x00
  Tx(K1/K2) : 0x00/0x00
  Remote Rx(K1/K2):  1/    Remote Tx(K1/K2):  1/


BER thresholds: SF = 10e-3 SD = 10e-6 TCA thresholds: B1 = 10e-6 B2 = 10e-6 B3 = 10e-6

  Optics type: VSR2000-3R2 (2km)
  Clock source: internal (actual) internal (configured)

Optical Power Monitoring (accuracy: +/- 1dB)
Rx power = 1.3796 mW, 1.4 dBm
Tx power = 1.7380 mW, 2.4 dBm
Tx laser current bias = 58.3 mA