North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

40Gbit private peer

  • From: Peter Lothberg
  • Date: Thu Aug 02 12:47:18 2007

SUnet (AS1653) and STUPI (AS1880) want to announce that 
we have brought up what we believe is the first private 
peer at 40G between two independent networks.

It speaks IPv4, IPv6 both unicast and multicast.

-Peter

------------------------------------------------------------------------

RP/0/RP0/CPU0:HFR1-F#sh int pos 0/3/0/0
POS0/3/0/0 is up, line protocol is up
  Interface state transitions: 2
  Hardware is Packet over SONET/SDH
  Description: OC768 Private Peering to Sunet <[email protected]>
  Internet address is 193.11.20.146/30
  MTU 4474 bytes, BW 39813120 Kbit
     reliability 255/255, txload 0/255, rxload 0/255
  Encapsulation HDLC, crc 32, controller loopback not set, keepalive set (10 sec)
  Last clearing of "show interface" counters 1d00h
  30 second input rate 77849000 bits/sec, 7236 packets/sec
  30 second output rate 17464000 bits/sec, 5023 packets/sec
     115627177 packets input, 155140727534 bytes, 0 total input drops
     0 drops for unrecognized upper-level protocol
     Received 0 runts, 0 giants, 0 throttles, 0 parity
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     78946374 packets output, 34499886901 bytes, 0 total output drops
     0 output errors, 0 underruns, 0 applique, 0 resets
     0 output buffer failures, 0 output buffers swapped out

RP/0/RP0/CPU0:HFR1-F#sh controllers soNET 0/3/0/0
Port SONET0/3/0/0:

Status: Up

Loopback: None

SECTION
  LOF = 0          LOS    = 0                            BIP(B1) = 0
LINE
  AIS = 0          RDI    = 0          FEBE = 0          BIP(B2) = 0
PATH
  AIS = 0          RDI    = 0          FEBE = 0          BIP(B3) = 0
  LOP = 0          NEWPTR = 0          PSE  = 0          NSE     = 0
  PLM = 0          TIM    = 0
Detected Alarms: None
Asserted Alarms: None
Mask for Detected->Asserted: None
Detected Alerts: None
Reported Alerts: None
Mask for Detected->Reported: None
Alarm reporting enabled for: SLOS SLOF SF_BER PLOP
Alert reporting enabled for: B1-TCA B2-TCA B3-TCA

Framing: SONET
SPE Scrambling: Enabled
C2 State: Stable   C2_rx = 0x16 (22)   C2_tx = 0x16 (22) / Scrambling Derived
S1S0(tx): 0x0  S1S0(rx): 0x0 / Framing Derived

PATH TRACE BUFFER : STABLE
  Remote hostname : c1sth-re1 so-7/0/0
  Remote interface:
  Remote IP addr  :

APS
No APS Group Configured
  Protect  Channel 0   DISABLED
  Rx(K1/K2) : 0x00/0x00
  Tx(K1/K2) : 0x00/0x00
  Remote Rx(K1/K2):  1/    Remote Tx(K1/K2):  1/


BER thresholds:  SF = 10e-3  SD = 10e-6
TCA thresholds:  B1 = 10e-6  B2 = 10e-6  B3 = 10e-6

  Optics type: VSR2000-3R2 (2km)
  Clock source: internal (actual) internal (configured)

Optical Power Monitoring (accuracy: +/- 1dB)
  Rx power = 1.3796 mW, 1.4 dBm
  Tx power = 1.7380 mW, 2.4 dBm
  Tx laser current bias = 58.3 mA