Re: Problems connectivity GE on Foundry BigIron to Cisco 2950T

  • From: Jeff Rosowski
  • Date: Mon Feb 06 12:51:06 2006


According to "Ethernet, The Definitive Guide", that feature is an
optional part of the spec.

One thing I've heard people encounter is that if they use a cross-over
cable, which probably really implies a 100BASE-TX cross-over, then the
ports only go to 100Mbps. A Gig-E rated straight through, in conjunction
with the automatic crossover feature, was necessary to get to GigE.
A lot of cross over cables only cross pairs 1-2 with 3-6, leaving 4-5, and 7-8 as straight through. Gig-E uses all four pair.