-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

Cisco Security Advisory: Default Administrative Password in Cisco Guard
and Traffic Anomaly Detector

Revision 1.0

For Public Release 2004 December 15 1900 UTC (GMT)

- ----------------------------------------------------------------------

Contents
========

    Summary
    Affected Products
    Details
    Impact
    Software Versions and Fixes
    Obtaining Fixed Software
    Workarounds
    Exploitation and Public Announcements
    Status of This Notice: FINAL
    Distribution
    Revision History
    Cisco Security Procedures

- ----------------------------------------------------------------------

Summary
=======

The Cisco Guard and Cisco Traffic Anomaly Detector software contains a
default password for an administrative account. This password is set,
without any user's intervention, during installation of the software
used by the Cisco Guard and Traffic Anomaly Detector Distributed
Denial of Service (DDoS) mitigation appliances, and is the same in all
installations of the product.

Software version 3.0 and earlier of the Cisco Guard and Traffic Anomaly
Detector are affected by this vulnerability. Customers running version
3.1 or higher of the software are not affected. There are workarounds
available including one that does not require a reboot of the device.
Cisco has made free software available to address this problem.

The vulnerabilities are documented as the following Cisco bug IDs:
CSCeg12167 and CSCeg12188.

This advisory is available at
http://www.cisco.com/warp/public/707/cisco-sa-20041215-guard.shtml.

Affected Products
=================

Vulnerable Products
- -------------------

All versions of the software for the Cisco Guard and Cisco Traffic
Anomaly Detector prior to version 3.1 are affected by this
vulnerability.

There are three ways to determine the software version that your Cisco
Guard and Cisco Traffic Anomaly Detector DDoS mitigation appliances are
running:

  * Virtual terminal or local serial console connection
  * Remote Secure Shell (SSH) connection
  * Remote secure web session

What follows is an example of each method; you should choose the method
that applies to your particular environment and network setup.

 1. To determine the software version number through the local serial
    console use a serial cable and a terminal emulation program to
    connect to the appliance. Once you are connected press the Enter
    key of your terminal and the Guard and Traffic Anomaly Detector
    will present, without even logging in, the version of the software
    running on the devices:

        Cisco Guard Version 3.1(0.12)

        GUARD login:


    In this example the Cisco Guard is running software version 3.1. For
    a virtual terminal the procedure is the same except that no serial
    cable or terminal emulation program is needed (a standard keyboard
    and monitor are directly connected to the appliance.)

 2. To obtain the software version number through a SSH session use a
    SSH client to log into the Cisco Guard or Cisco Traffic Anomaly
    Detector and issue the show version command-line interface (CLI)
    command. The following example shows an interaction with a Cisco
    Traffic Anomaly Detector:

        prompt$ ssh [email protected]
        [email protected]'s password:
        Last login: Wed Nov 24 22:45:53 on ttyS0
        [email protected]#show version
        Copyright (c) 2000-2004 Cisco Systems, Inc. All rights reserved.

        Software License Agreement

        [...]

        Cisco Anomaly Detector
        Release: 3.1(0.12)
        Date:    2004/10/27 19:58:14

        DETECTOR uptime is 3 weeks, 3 days, 17 hours, 53 minutes
        System Serial Number:  XXXXXXX

        Contact Information:
           Cisco Systems Inc.
           [email protected]
        [email protected]#


    In this example the Cisco Traffic Anomaly Detector is running
    software version 3.1.

 3. To obtain the software version that Cisco Guard and Cisco Traffic
    Anomaly Detector are running through a secure web interface, open
    the URL https://<IP address of your Guard or Detector>/ in a web
    browser, log in, and then click on the About link located on the top
    right section of the browser window.

Products Confirmed Not Vulnerable
- ---------------------------------

No other Cisco products are currently known to create these specific
default account/passwords.

Details
=======

The Cisco Guard and Cisco Traffic Anomaly Detectors are Distributed
Denial of Service (DDoS) attack mitigation appliances that detect the
presence of a potential DDoS attack and divert attack traffic destined
for the network being monitored without affecting the flow of legitimate
traffic.

Both the Cisco Guard and the Cisco Anomaly Traffic Detector appliances
can be managed via a virtual terminal (standard keyboard and monitor
attached directly to the appliance), a local serial console, remote SSH
connections, and/or remote secure web sessions. Most management and
troubleshooting tasks are performed through a CLI interface that is
similar to that of most Cisco products, but a special administrative
account is provided so certain management and troubleshooting tasks that
are not covered by the standard CLI can be performed. The administrative
account username is root, like the superuser in the Unix operating
system.

This account has a default password that is the same in all
installations of the Cisco Guard and Cisco Traffic Anomaly Detector
in all versions prior to 3.1. This default password is made up of a
combination of letters, numbers, and punctuation per best security
practices for passwords, but Cisco recommends that this password be
changed for extra security.

The vulnerability described here is documented in the Cisco Bug ID
CSCeg12167 for the Cisco Guard and in the Cisco Bug ID CSCeg12188 for
the Cisco Traffic Anomaly Detector.

Impact
======

Someone that is able to log into a Cisco Guard or Cisco Traffic Anomaly
Detector DDoS mitigation appliance using the root administrative account
has full control of the device, which includes the ability to change
configurations, divert traffic, and install software.

Software Versions and Fixes
===========================

While workarounds that do not require a software upgrade exist, Cisco
has made available free software that addresses the vulnerability
described in this document.

Version 3.1 or later of the Cisco Guard and Cisco Traffic Anomaly
Detector software does not leave a default password for the
administrative root account after a fresh installation or after an
upgrade from previous versions. This is because in version 3.1 and
later the installation/upgrade procedure requires the user to choose a
password for the administrative account.

Note: the procedure to upgrade to version 3.1 can only be done through
the out-of-band interfaces.

When considering software upgrades, please also consult
http://www.cisco.com/en/US/products/products_security_advisories_listing.html
and any subsequent advisories to determine exposure and a complete
upgrade solution.

In all cases, customers should exercise caution to be certain the
devices to be upgraded contain sufficient memory and that current
hardware and software configurations will continue to be supported
properly by the new release. If the information is not clear, contact
the Cisco Technical Assistance Center ("TAC") for assistance.

If affected customers are not able to upgrade the software, the
workarounds presented in the Workarounds section can be employed to
completely eliminate this vulnerability.

Obtaining Fixed Software
========================

As the fix for this vulnerability is a default configuration change, and
a workaround is available, a software upgrade is not required to address
this vulnerability. However, if you have a service contract, and wish
to upgrade to unaffected code, you may obtain upgraded software through
your regular update channels once that software is available. For most
customers, this means that upgrades should be obtained through the
Software Center on Cisco's Worldwide Web site at http://www.cisco.com.

If you need assistance with the implementation of the workarounds, or
have questions on the workarounds, please contact the Cisco Technical
Assistance Center (TAC).

  * +1 800 553 2447 (toll free from within North America)
  * +1 408 526 7209 (toll call from anywhere in the world)
  * e-mail: [email protected]

See http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml for
additional TAC contact information, including special localized
telephone numbers and instructions and e-mail addresses for use in
various languages.

Customers may only install and expect support for the feature
sets they have purchased. By installing, downloading, accessing
or otherwise using such software upgrades, customers agree to
be bound by the terms of Cisco's software license terms found
at http://www.cisco.com/public/sw-license-agreement.html,
or as otherwise set forth at Cisco.com Downloads at
http://www.cisco.com/public/sw-center/sw-usingswc.shtml.

Workarounds
===========

The vulnerability described in this document can be eliminated
completely by logging into the affected Cisco Guard and Cisco Traffic
Anomaly Detector DDoS mitigation appliances and changing the default
password for the administrative root account to a strong password chosen
by the user.

To change the default password you need to run the passwd command once
you have logged in as the root user. The following interaction shows and
example of a change password dialog in a Cisco Traffic Anomaly Detector
that is performed via SSH:

    prompt$ ssh [email protected]
    [email protected]'s password:
    Last login: Tue Nov 23 15:48:13 on ttyS0
    [[email protected] root]# passwd
    Changing password for user root.
    New password: <new password typed in here>
    Retype new password: <new password typed in here>
    passwd: all authentication tokens updated successfully.

In order to perform this procedure you will need the default password.
To obtain this password customers must contact the Cisco TAC.
Entitlement will be checked so please have your product serial number
available and give the URL of this notice.

After changing the default password, the Cisco Guard and Traffic Anomaly
Detector will not accept root logins using the default password.

A reboot is not required for the new password to take effect, so network
operations will not be disrupted.

If affected customers do not wish to contact Cisco to obtain the default
password, it is possible to change the administrative account's password
by performing the password recovery procedure. This procedure is
documented at the following location:

http://cisco.com/en/US/products/ps5887/products_password_recovery09186a008037942b.shtml

As a security best practice, it is recommended that customers make use
of the access control feature that restricts connectivity to the SSH and
web-based management services to certain IP networks configured by the
administrator. Refer to the documentation for your Cisco Guard and Cisco
Traffic Anomaly Detector, specifically the permit wbm and permit ssh
commands, for details on how to enable this feature. Having these access
control mechanisms in place may mitigate the vulnerability if it cannot
be eliminated completely by changing the default password as described
above.

Exploitation and Public Announcements
=====================================

The Cisco PSIRT is not aware of any public announcements or malicious
use of the vulnerability described in this advisory.

This vulnerability was uncovered during internal code audit.

Status of This Notice: FINAL
============================

THIS ADVISORY IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY
KIND OF GUARANTEE OR WARRANTY. YOUR USE OF THE INFORMATION ON THE
ADVISORY OR MATERIALS LINKED FROM THE ADVISORY IS AT YOUR OWN RISK.
CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS NOTICE AT ANY TIME.

Distribution
============

This advisory will be posted on Cisco's worldwide website at
http://www.cisco.com/warp/public/707/cisco-sa-20041215-guard.shtml.

In addition to worldwide web posting, a text version of this notice is
clear-signed with the Cisco PSIRT PGP key and is posted to the following
e-mail and Usenet news recipients:

  * [email protected]
  * [email protected] (includes CERT/CC)
  * [email protected]
  * [email protected]
  * [email protected]
  * [email protected]
  * [email protected]
  * [email protected]

Future updates of this advisory, if any, will be placed on Cisco's
worldwide website, but may or may not be actively announced on mailing
lists or newsgroups. Users concerned about this problem are encouraged
to check the above URL for any updates.

Revision History
================

+---------------------------------------------+
| Revision |                  | Initial       |
| 1.0      | 2004-December-15 | public        |
|          |                  | release.      |
+---------------------------------------------+

Cisco Security Procedures
=========================

Complete information on reporting security vulnerabilities
in Cisco products, obtaining assistance with security
incidents, and registering to receive security information
from Cisco, is available on Cisco's worldwide website at
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html.
This includes instructions for press inquiries regarding
Cisco security notices. All Cisco security advisories are available at
http://www.cisco.com/go/psirt.

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.2.5 (GNU/Linux)

iD8DBQFBwJadezGozzK2tZARAvqjAJ0VQ8rC3EpQQZVeICjfQbB5/WY3EgCg985B
KdQz4NFAbwgoDaInXmWjs7c=
=chLH