North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: Multi-link Frame Relay OR Load Balancing

  • From: Edward B. Dreger
  • Date: Sat Sep 18 10:36:54 2004

je> Date: Thu, 16 Sep 2004 16:44:48 -0600
je> From: james edwards

je> FWIW, I asked about MLFR on the cisco-nsp and one person
je> responded indicating he worked for some time with Cisco on
je> trying to get MLFR to work but never resolved out of order
je> and dropped packet issues. What hardware are you considering

I must have missed your post, or I'd have chimed in.  I've noted
MFR flakiness (dropped packets, sudden interface down, additional
links become unbonded and refuse to bond again, MTU troubles with
MPLS, wedged processes, etc.) on 12.3 and 12.3T.

Bryce, you might also consider an M13 mux if worried about loop
reliability.  However, at this point, I'd place my bets on a DS3
loop as opposed to several MFR-ified T1s. :-/


Eddy
--
Everquick Internet - http://www.everquick.net/
A division of Brotsman & Dreger, Inc. - http://www.brotsman.com/
Bandwidth, consulting, e-commerce, hosting, and network building
Phone: +1 785 865 5885 Lawrence and [inter]national
Phone: +1 316 794 8922 Wichita