North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

RE: Quick circuit question.

  • From: Hannigan, Martin
  • Date: Tue Jul 06 19:09:09 2004


Just to be accurate, DS is digital service cross connect
i.e. dsx1 panel, dsx3 panel, etc. Typically a ds0 cross connect is 
referred to as "ds0 wire frame" since it's muxed up to ds1's via
DSX1 bays. 

A DSX panel is basically a piece of dumb equipment, sometimes fitted
with led port tracers(useful)that you can configure in interconnect, one
card, or cross connect, two card, modes for testing both sides, good add
move, drop capability, etc.

-M



--
Martin Hannigan                         (c) 617-388-2663
VeriSign, Inc.                          (w) 703-948-7018
Network Engineer IV                       Operations & Infrastructure
[email protected]



> -----Original Message-----
> From: [email protected] [mailto:[email protected]]On Behalf Of
> Edward B. Dreger
> Sent: Tuesday, July 06, 2004 6:55 PM
> To: ''[email protected]''
> Subject: RE: Quick circuit question.
> 
> 
> 
> > Date: Tue, 6 Jul 2004 14:45:44 -0500
> > From: [email protected]
> 
> > Finally, "dsx" does not stand for full duplex, as someone
> 
> DSx = DS0/DS1/DS3 (using "x" as wildcard).  Not to be confused
> with uppercase "X".
> 
> 
> Eddy
> --
> EverQuick Internet - http://www.everquick.net/
> A division of Brotsman & Dreger, Inc. - http://www.brotsman.com/
> Bandwidth, consulting, e-commerce, hosting, and network building
> Phone: +1 785 865 5885 Lawrence and [inter]national
> Phone: +1 316 794 8922 Wichita
> _________________________________________________________________
> DO NOT send mail to the following addresses:
> [email protected] -*- [email protected] -*- [email protected]
> Sending mail to spambait addresses is a great way to get blocked.
>