Matt Ryan wrote:

Do you get commission from Juniper?


Where do I get my comission then? Iīve described inferior product as such many times
and so far I havenīt seen deposits from vendors in my bank account?

!!OT warning!!

Pete

Matt.

-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: 30 January 2004 16:51
Cc: [email protected]
Subject: RE: CIsco 7206VXR w/NPE-G1 Question



Keep in mind, 72xx is still flow-based, so you need to count *both* shared fabric capacity (aka PCI buses) and capacity of NPE to establish flows (aka pps rate).

NPE-G1 might probably route 3*GE, without any services and if all 3GE are in a single flow, but will melt down at a face of one-packet-per-flow DDoS (read: "Nachi" worm) at a far lower rate (I'd be surprised if it sustains 200kpps DDoS traffic, which can be as low as 150Mbit bandwidth).
That is of course, as opposed to Juniper, which is truly line-rate at any
interface, with any services, at any composition of traffic.

-alex

On Fri, 30 Jan 2004 [email protected] wrote:


Does anyone have definitive speed results on the 3 "built-in" Gig ports
on the NPE-G1? I know that they aren't attached to the PCI Buses, and
don't consume bandwidth points, but all of that is mute. Can all three
of the ports do line rate Gig? The Gig PA is limited to 400Mbps. I
have seen posts that allude to the fact the max throughput on the 3 Gigs
are 800Mbps. It's is like a big mystery that cannot be solved. With a
"J" M7i, I know I'm going to get line rate per port up to the total
forwarding capacity of the FPC.

We are trying to create a comparison matrix and any info you have would
be great.

Jack


-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of
Simon Hamilton-Wilkes
Sent: Friday, January 30, 2004 9:36 AM
To: [email protected]
Subject: RE: CIsco 7206VXR w/NPE-G1 Question



One more interesting feature - if you need a 4th GigE port, you can add
the GigE I/O card which still uses none of the bus bandwidth points.
The buses are fine for OC3 and below...


Simon



****************************************************************************
**************

The information contained in this message, including attachments, may

contain
privileged or confidential information that is intended to be delivered

only to the
person identified above. If you are not the intended recipient, or the

person
responsible for delivering this message to the intended recipient, ALLTEL

requests
that you immediately notify the sender and asks that you do not read the

message or its
attachments, and that you delete them without copying or sending them to

anyone else.



------------------------------------------------------------------------------
Live Life in Broadband
www.telewest.co.uk


The information transmitted is intended only for the person or entity to which it is addressed and may contain confidential and/or privileged material.
Statements and opinions expressed in this e-mail may not represent those of the company. Any review, retransmission, dissemination or other use of, or taking of any action in reliance upon, this information by persons or entities other than the intended recipient is prohibited. If you received this in error, please contact the sender immediately and delete the material from any computer.

==============================================================================