North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical Re: Bandwidth Control Question
> The quite annoying thing about that is switching a PC-MC-2T3+ interface > from channelized (the default) to unchannelized causes a cbus complex > restart, which interrupts traffic through the router for a period of > time (the time varies based on the number of interfaces in the router). Even with "service single-slot-reload-enable"? Steinar Haug, Nethelp consulting, [email protected]
|