Re: Bandwidth Control Question

  • From: sthaug
  • Date: Fri Dec 19 12:41:03 2003

> The quite annoying thing about that is switching a PC-MC-2T3+ interface
> from channelized (the default) to unchannelized causes a cbus complex
> restart, which interrupts traffic through the router for a period of
> time (the time varies based on the number of interfaces in the router).

Even with "service single-slot-reload-enable"?

Steinar Haug, Nethelp consulting, [email protected]