North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: Cisco IOS Failure due to Virus

  • From: Robert Blayzor
  • Date: Wed Sep 10 23:18:48 2003

On 9/10/03 10:58 PM, "Richard J.Sears" <[email protected]> wrote:

> %SYS-2-MALLOCFAIL: Memory allocation of 704 bytes failed from
> 0x60329F00, alignment 0
> Pool: Processor  Free: 92744  Cause: Memory fragmentation
> Alternate Pool: None  Free: 0  Cause: No Alternate pool
> -Process= "Pool Manager", ipl= 0, pid= 6
> -Traceback= 6038049C 60382200 60329F08 6038DEDC
> 
> %TCP-6-NOBUFF: TTY0, no buffer available
> -Process= "BGP Router", ipl= 0, pid= 132
> 
> %% Low on memory; try again later

Did you enable CEF?
Are you dropping 92 byte ICMP packets where needed?

--
Robert Blayzor, BOFH
INOC, LLC
[email protected]
PGP: http://www.inoc.net/~dev/
Key fingerprint = A445 7D1E 3D4F A4EF 6875  21BB 1BAA 10FE 5748 CFE9

"I don't need parents. All I need is a recording that says, 'Go play
outside!" - Calvin and Hobbes