On Wednesday, August 27, 2003, at 11:10 PM, Edward Murphy wrote:

Is anyone having this problem on a unit with the mad-2 cards?


We are not experiencing the reboots/lock ups on our APX 8000.

We are using the Ethernet card with the dongle. E-100-V I think.
We are using the Channelized DS-3 card

We are using 96 port madd2 modem cards (5 modem cards, 480 modems)

Our APX is not even close to 25% capacity.

admin> show
Controller { left-controller } ( PRIMARY ):
Reqd Oper Slot Type
{ right-controller } UP UP ( SECONDARY )
{ shelf-1 slot-34 0 } UP UP madd2-card
{ shelf-1 slot-35 0 } UP UP madd2-card
{ shelf-1 slot-36 0 } UP UP madd2-card
{ shelf-1 slot-37 0 } UP UP madd2-card
{ shelf-1 slot-38 0 } UP UP madd2-card
{ shelf-1 slot-39 0 } UP UP t3-card
{ shelf-1 slot-40 0 } UP UP ether3-card
admin>

admin> list
[in SLOT-INFO/{ shelf-1 slot-39 0 }]
slot-address* = { shelf-1 slot-39 0 }
serial-number = 1038406179
software-version = 10.0
software-revision = 2
software-level = ""
hardware-level = " K"
software-release = ""

admin> read slot-info {1 40 }
SLOT-INFO/{ shelf-1 slot-40 0 } read
admin> list
[in SLOT-INFO/{ shelf-1 slot-40 0 }]
slot-address* = { shelf-1 slot-40 0 }
serial-number = 10516825
software-version = 10.0
software-revision = 2
software-level = ""
hardware-level = " C"
software-release = ""

admin> ls
ls Flash card 1:
/:
current/ 0 Fri Sep 29 11:36:36 2000
/current:
tntt3.ffs 416034 Mon Dec 16 19:47:20 2002 Version 10.0.2
tntmadd.ffs 1726366 Mon Dec 16 19:51:10 2002 Version 10.0.2
tntenet3.ffs 446882 Mon Dec 16 19:48:22 2002 Version 10.0.2