After I upgraded my
IOS this morning I've seen 13,844 input errors on the port; when looking
at the switch the router is connected to I see that a very similar number of
multi-cast packets (13,423).
Has anyone else seen
this? Is this perhaps what the patch does (register exploit packets as
input errors)?
FastEthernet0/0 is
up, line protocol is up
Hardware is DEC21140A,
address is 0002.1723.0800 (bia 0002.1723.0800)
Internet
address is 199.185.131.249/24
MTU 1500
bytes, BW 100000 Kbit, DLY 100 usec,
reliability 255/255, txload 106/255, rxload 118/255
Encapsulation
ARPA, loopback not set
Keepalive set
(10 sec)
Full-duplex,
100Mb/s, 100BaseTX/FX
ARP type:
ARPA, ARP Timeout 04:00:00
Last input
00:00:00, output 00:00:00, output hang never
Last clearing
of "show interface" counters never
Input queue:
0/75/53/231 (size/max/drops/flushes); Total output drops: 733
Queueing
strategy: fifo
Output queue:
0/40 (size/max)
5 minute input
rate 46298000 bits/sec, 9642 packets/sec
5 minute
output rate 41710000 bits/sec, 8891 packets/sec
163709405 packets input, 2006456215 bytes
Received 11374 broadcasts, 0 runts, 0 giants, 2 throttles
13844 input errors, 0 CRC, 0 frame, 0 overrun, 13182 ignored
0 watchdog
0 input packets with dribble condition detected
157777703 packets output, 1121349334 bytes, 0 underruns
0 output errors, 0 collisions, 2 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
FastEthernet8 is up
Hardware is FastEthernet,
address is 00e0.5202.4613 (bia 00e0.5202.4613)
Configured
speed 100Mbit, actual 100Mbit, configured duplex fdx, actual fdx
Member of L2
VLAN ID 1, port is untagged, port state is FORWARDING
STP configured
to OFF, priority is high, flow control enabled
mirror
disabled, monitor disabled
Not member of
any active trunks
Not member of
any configured trunks
No port name
5 minute input
rate: 43045336 bits/sec, 8985 packets/sec, 44.47% utilization
5 minute
output rate: 46621104 bits/sec, 9711 packets/sec, 48.16% utilization
689714869
packets input, 3817420687 bytes, 0 no buffer
Received 4493
broadcasts, 0 runts, 0 giants
5 input
errors, 5 CRC, 0 frame, 0 ignored
13423 multicast
736196013
packets output, 1836390208 bytes, 0 underruns
0 output
errors, 0 collisions
________________________
saxon
jones
network
infrastructure admin
interbaun communications
suite
200
18404
stony plain road
edmonton,
ab
T5S
2M8
mailto:[email protected]