North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: 2 Wire T1 - HDLC

  • From: Jared Mauch
  • Date: Tue May 15 14:19:54 2001

	I have 2 T1's that are delivered as a single pair per T1.

	- Jared

On Mon, May 14, 2001 at 05:41:01PM -0400, mike harrison wrote:
> 
> John Tamplin:
> > the smartjack extracts the T1 -- I have two of these in my house, using
> > Pairgain (now ADC)'s HiGain Solitaire H2TU.R402 for T1 transport.  The URL
> > of the frame describing the product line is at (minus any line breaks or 
> > spaces added along the way): 
> > http://www6.adc.com/ecom/wps?lineid=OND2737&group=T1%2bTransport%252FHiGain&EXPAND=OND50995&L=EC_List_Group_Index.html&R=WPS_Out_Hierarchy.html&ID=OND50995
> > This specific card is under HDSL2 RT Modules.
> 
> Thats the units we have on the wall for some recent T1 installs as well.
> So far working very well.. Yes, it is HDSL, It's not 2 x 786K sDSL or
> whatever as stated in the original posted email that I responded to.
> 
> Whats funny is I got 2 private emails from BellSouth engineering types
> that did not know they were being installed in this region. 
> 
> 
> 
> 
> 
> 
> 

-- 
Jared Mauch  | pgp key available via finger from [email protected]
clue++;      | http://puck.nether.net/~jared/  My statements are only mine.