North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical Re: More 6509 problems...
On Thu, Feb 01, 2001 at 06:21:48PM -0500, Rodney Dunn wrote: > > Danny, > > The interface status should be independent of > the swithcing path. I've never seen the line > state be affected by the switching mechanism > (although I have seen the opposite). > > Can you email me the case# you had so I can take > a look? I have, because the line state can be controlled by the keepalive. If the keepalive don't get through because of the switching path ..... > > rodney > > > On Tue, Jan 30, 2001 at 02:22:21PM -0600, Danny Snyder wrote: > > > > Ya got me on that one....Cisco didn't really say why and I didn't think to > > ask them either.... > > > > --Danny > > > > > > > > > > -----Original Message----- > > From: Kenny Sallee [mailto:[email protected]] > > Sent: Tuesday, January 30, 2001 11:28 AM > > To: [email protected]; 'Danny Snyder' > > Cc: [email protected] > > Subject: Re: More 6509 problems... > > > > > > How would CEF cause an interface to be up/down? Just curious....Kenny > > > > ----- Original Message ----- > > From: "Alison Gudgeon" <[email protected]> > > To: "'Danny Snyder'" <[email protected]>; <[email protected]> > > Sent: Tuesday, January 30, 2001 8:36 AM > > Subject: RE: More 6509 problems... > > > > > > > > > > Hi > > > > > > Hybrid IOS > > > > > > I've got IP CEF DISTRIBUTED set globally. Did you have it enabled or > > > disabled on the T3 interface? > > > > > > Ali > > > > > > -----Original Message----- > > > From: Danny Snyder [mailto:[email protected]] > > > Sent: 30 January 2001 16:21 > > > To: [email protected]; [email protected] > > > Subject: RE: More 6509 problems... > > > > > > > > > Alison, > > > > > > I've had VERY similar problems with a 6509 (Sup 1a + MSFC2) with a FlexWAN > > > and a PA-2T3+. After spending the better part of two weeks on the phone > > > with Cisco, we finally determined that ip cef distributed needed to be > > > turned on in global configuration. > > > > > > Also, are you running native IOS or Catalyst OS on the Supervisor and IOS > > on > > > the MSFC ? > > > > > > Danny Snyder > > > Network Administrator > > > NowDocs, Inc. > > > > > > > > > > > > > > > -----Original Message----- > > > From: [email protected] [mailto:[email protected]]On Behalf Of > > > Alison Gudgeon > > > Sent: Tuesday, January 30, 2001 10:18 AM > > > To: [email protected] > > > Subject: More 6509 problems... > > > > > > > > > > > > Hi, > > > > > > Is anyone doing the following: > > > > > > 6509 (supervisor 1a + msfc) - with a flexWAN adapter to take a Packet Over > > > Sonet OC-3 card. > > > > > > I'm having great problems getting up/up on the interface, the current > > > situation is up/down, a hardware loop at the telco kit brings the line > > up/up > > > but otherwise just up/down. Config is default I've just put IP's on. > > > > > > I'm running very new code - 12.1(4)E1 > > > > > > many thanks in advance for any help. > > > > > > > > > Kind Regards > > > > > > > > > Alison > > > > > > > > -- Regards, Ulf. --------------------------------------------------------------------- Ulf Zimmermann, 1525 Pacific Ave., Alameda, CA-94501, #: 510-769-2936 Alameda Networks, Inc. | http://www.Alameda.net | Fax#: 510-521-5073
|