North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: More 6509 problems...

  • From: Rodney Dunn
  • Date: Thu Feb 01 18:26:29 2001

Danny,

The interface status should be independent of
the swithcing path.  I've never seen the line
state be affected by the switching mechanism
(although I have seen the opposite).

Can you email me the case# you had so I can take 
a look?

rodney


On Tue, Jan 30, 2001 at 02:22:21PM -0600, Danny Snyder wrote:
> 
> Ya got me on that one....Cisco didn't really say why and I didn't think to
> ask them either....
> 
> --Danny
> 
> 
> 
> 
> -----Original Message-----
> From: Kenny Sallee [mailto:[email protected]]
> Sent: Tuesday, January 30, 2001 11:28 AM
> To: [email protected]; 'Danny Snyder'
> Cc: [email protected]
> Subject: Re: More 6509 problems...
> 
> 
> How would CEF cause an interface to be up/down?  Just curious....Kenny
> 
> ----- Original Message -----
> From: "Alison Gudgeon" <[email protected]>
> To: "'Danny Snyder'" <[email protected]>; <[email protected]>
> Sent: Tuesday, January 30, 2001 8:36 AM
> Subject: RE: More 6509 problems...
> 
> 
> >
> > Hi
> >
> > Hybrid IOS
> >
> > I've got IP CEF DISTRIBUTED set globally.  Did you have it enabled or
> > disabled on the T3 interface?
> >
> > Ali
> >
> > -----Original Message-----
> > From: Danny Snyder [mailto:[email protected]]
> > Sent: 30 January 2001 16:21
> > To: [email protected]; [email protected]
> > Subject: RE: More 6509 problems...
> >
> >
> > Alison,
> >
> > I've had VERY similar problems with a 6509 (Sup 1a + MSFC2) with a FlexWAN
> > and a PA-2T3+.  After spending the better part of two weeks on the phone
> > with Cisco, we finally determined that ip cef distributed needed to be
> > turned on in global configuration.
> >
> > Also, are you running native IOS or Catalyst OS on the Supervisor and IOS
> on
> > the MSFC ?
> >
> > Danny Snyder
> > Network Administrator
> > NowDocs, Inc.
> >
> >
> >
> >
> > -----Original Message-----
> > From: [email protected] [mailto:[email protected]]On Behalf Of
> > Alison Gudgeon
> > Sent: Tuesday, January 30, 2001 10:18 AM
> > To: [email protected]
> > Subject: More 6509 problems...
> >
> >
> >
> > Hi,
> >
> > Is anyone doing the following:
> >
> > 6509 (supervisor 1a + msfc) - with a flexWAN adapter to take a Packet Over
> > Sonet OC-3 card.
> >
> > I'm having great problems getting up/up on the interface, the current
> > situation is up/down, a hardware loop at the telco kit brings the line
> up/up
> > but otherwise just up/down.  Config is default I've just put IP's on.
> >
> > I'm running very new code - 12.1(4)E1
> >
> > many thanks in advance for any help.
> >
> >
> > Kind Regards
> >
> >
> > Alison
> >
> >
>