North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical Re: More 6509 problems...
Danny, The interface status should be independent of the swithcing path. I've never seen the line state be affected by the switching mechanism (although I have seen the opposite). Can you email me the case# you had so I can take a look? rodney On Tue, Jan 30, 2001 at 02:22:21PM -0600, Danny Snyder wrote: > > Ya got me on that one....Cisco didn't really say why and I didn't think to > ask them either.... > > --Danny > > > > > -----Original Message----- > From: Kenny Sallee [mailto:[email protected]] > Sent: Tuesday, January 30, 2001 11:28 AM > To: [email protected]; 'Danny Snyder' > Cc: [email protected] > Subject: Re: More 6509 problems... > > > How would CEF cause an interface to be up/down? Just curious....Kenny > > ----- Original Message ----- > From: "Alison Gudgeon" <[email protected]> > To: "'Danny Snyder'" <[email protected]>; <[email protected]> > Sent: Tuesday, January 30, 2001 8:36 AM > Subject: RE: More 6509 problems... > > > > > > Hi > > > > Hybrid IOS > > > > I've got IP CEF DISTRIBUTED set globally. Did you have it enabled or > > disabled on the T3 interface? > > > > Ali > > > > -----Original Message----- > > From: Danny Snyder [mailto:[email protected]] > > Sent: 30 January 2001 16:21 > > To: [email protected]; [email protected] > > Subject: RE: More 6509 problems... > > > > > > Alison, > > > > I've had VERY similar problems with a 6509 (Sup 1a + MSFC2) with a FlexWAN > > and a PA-2T3+. After spending the better part of two weeks on the phone > > with Cisco, we finally determined that ip cef distributed needed to be > > turned on in global configuration. > > > > Also, are you running native IOS or Catalyst OS on the Supervisor and IOS > on > > the MSFC ? > > > > Danny Snyder > > Network Administrator > > NowDocs, Inc. > > > > > > > > > > -----Original Message----- > > From: [email protected] [mailto:[email protected]]On Behalf Of > > Alison Gudgeon > > Sent: Tuesday, January 30, 2001 10:18 AM > > To: [email protected] > > Subject: More 6509 problems... > > > > > > > > Hi, > > > > Is anyone doing the following: > > > > 6509 (supervisor 1a + msfc) - with a flexWAN adapter to take a Packet Over > > Sonet OC-3 card. > > > > I'm having great problems getting up/up on the interface, the current > > situation is up/down, a hardware loop at the telco kit brings the line > up/up > > but otherwise just up/down. Config is default I've just put IP's on. > > > > I'm running very new code - 12.1(4)E1 > > > > many thanks in advance for any help. > > > > > > Kind Regards > > > > > > Alison > > > > >
|