North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

RE: More 6509 problems...

  • From: Danny Snyder
  • Date: Thu Feb 01 15:40:23 2001

Ya got me on that one....Cisco didn't really say why and I didn't think to
ask them either....

--Danny




-----Original Message-----
From: Kenny Sallee [mailto:[email protected]]
Sent: Tuesday, January 30, 2001 11:28 AM
To: [email protected]; 'Danny Snyder'
Cc: [email protected]
Subject: Re: More 6509 problems...


How would CEF cause an interface to be up/down?  Just curious....Kenny

----- Original Message -----
From: "Alison Gudgeon" <[email protected]>
To: "'Danny Snyder'" <[email protected]>; <[email protected]>
Sent: Tuesday, January 30, 2001 8:36 AM
Subject: RE: More 6509 problems...


>
> Hi
>
> Hybrid IOS
>
> I've got IP CEF DISTRIBUTED set globally.  Did you have it enabled or
> disabled on the T3 interface?
>
> Ali
>
> -----Original Message-----
> From: Danny Snyder [mailto:[email protected]]
> Sent: 30 January 2001 16:21
> To: [email protected]; [email protected]
> Subject: RE: More 6509 problems...
>
>
> Alison,
>
> I've had VERY similar problems with a 6509 (Sup 1a + MSFC2) with a FlexWAN
> and a PA-2T3+.  After spending the better part of two weeks on the phone
> with Cisco, we finally determined that ip cef distributed needed to be
> turned on in global configuration.
>
> Also, are you running native IOS or Catalyst OS on the Supervisor and IOS
on
> the MSFC ?
>
> Danny Snyder
> Network Administrator
> NowDocs, Inc.
>
>
>
>
> -----Original Message-----
> From: [email protected] [mailto:[email protected]]On Behalf Of
> Alison Gudgeon
> Sent: Tuesday, January 30, 2001 10:18 AM
> To: [email protected]
> Subject: More 6509 problems...
>
>
>
> Hi,
>
> Is anyone doing the following:
>
> 6509 (supervisor 1a + msfc) - with a flexWAN adapter to take a Packet Over
> Sonet OC-3 card.
>
> I'm having great problems getting up/up on the interface, the current
> situation is up/down, a hardware loop at the telco kit brings the line
up/up
> but otherwise just up/down.  Config is default I've just put IP's on.
>
> I'm running very new code - 12.1(4)E1
>
> many thanks in advance for any help.
>
>
> Kind Regards
>
>
> Alison
>
>