North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical RE: More 6509 problems...
7206vxr.. I've another stm-1 between london and manchester 7206vxr on both sides which works fine - the POS-OC3-SMI card is the same card on both the 7200 and the 6500. The configs are totally default.....I wonder if I have an IOS problem Ali -----Original Message----- From: Danny Snyder [mailto:[email protected]] Sent: 28 January 2001 16:44 To: [email protected]; [email protected] Subject: RE: More 6509 problems... I didn't specifically change any of the CEF configuration for the DS3 interface. As soon as I enabled ip cef distributed, the DS3 interfaces started working immediately. What hardware do you have at the end of the circuit opposite the 6509 ? --Danny -----Original Message----- From: Alison Gudgeon [mailto:[email protected]] Sent: Tuesday, January 30, 2001 10:36 AM To: 'Danny Snyder'; [email protected] Subject: RE: More 6509 problems... Hi Hybrid IOS I've got IP CEF DISTRIBUTED set globally. Did you have it enabled or disabled on the T3 interface? Ali -----Original Message----- From: Danny Snyder [mailto:[email protected]] Sent: 30 January 2001 16:21 To: [email protected]; [email protected] Subject: RE: More 6509 problems... Alison, I've had VERY similar problems with a 6509 (Sup 1a + MSFC2) with a FlexWAN and a PA-2T3+. After spending the better part of two weeks on the phone with Cisco, we finally determined that ip cef distributed needed to be turned on in global configuration. Also, are you running native IOS or Catalyst OS on the Supervisor and IOS on the MSFC ? Danny Snyder Network Administrator NowDocs, Inc. -----Original Message----- From: [email protected] [mailto:[email protected]]On Behalf Of Alison Gudgeon Sent: Tuesday, January 30, 2001 10:18 AM To: [email protected] Subject: More 6509 problems... Hi, Is anyone doing the following: 6509 (supervisor 1a + msfc) - with a flexWAN adapter to take a Packet Over Sonet OC-3 card. I'm having great problems getting up/up on the interface, the current situation is up/down, a hardware loop at the telco kit brings the line up/up but otherwise just up/down. Config is default I've just put IP's on. I'm running very new code - 12.1(4)E1 many thanks in advance for any help. Kind Regards Alison
|