On Mon, Jun 12, 2000 at 10:38:35PM +0200, Marc Teichtahl wrote:
> 
> can anyone translate this for me ?
> > Jun 12 21:41:07.679 CED: %RSP-3-RESTART: cbus complex
> > Jun 12 21:41:55.996 CED: %DBUS-3-SW_NOTRDY: DBUS software not ready
> after
> > dbus_s
> > lot_enable(), elapsed 12032, status 0x48
> > -Traceback= 602A5284 602A6418 602B808C 60287EAC 602879B0 60290B18
> 6023F2CC
> > 6023F
> > 2B8
> > Jun 12 21:42:06.504 CED: %CBUS-3-CCBPTIMEOUT: CCB handover timed out,
> CCB
> > 0x5800
> > FF20, slot 0
> > -Traceback= 602BA350 602B7B98 602B8178 60287EAC 602879B0 60290B18
> 6023F2CC
> > 6023F
> > 2B8

I had the same error messages with a slave RSP card after hot swapping.
On Ciscos recommendation they sent us a new one in 2 hours and everything
worked fine again.

> 
> 
> -- 
> 
> 
> Marc Teichtahl				Manager, Data Network Engineering
> Versa(tel Telecom			NASDAQ: VRSA AEX: VERSA
> 
> US Cell: +1 650 248 7058		Dutch Cell: +31 6 21213104
> 

-- 
Regards, Ulf.

---------------------------------------------------------------------