North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical Re: 7507 debug error
On Mon, Jun 12, 2000 at 10:38:35PM +0200, Marc Teichtahl wrote: > > can anyone translate this for me ? > > Jun 12 21:41:07.679 CED: %RSP-3-RESTART: cbus complex > > Jun 12 21:41:55.996 CED: %DBUS-3-SW_NOTRDY: DBUS software not ready > after > > dbus_s > > lot_enable(), elapsed 12032, status 0x48 > > -Traceback= 602A5284 602A6418 602B808C 60287EAC 602879B0 60290B18 > 6023F2CC > > 6023F > > 2B8 > > Jun 12 21:42:06.504 CED: %CBUS-3-CCBPTIMEOUT: CCB handover timed out, > CCB > > 0x5800 > > FF20, slot 0 > > -Traceback= 602BA350 602B7B98 602B8178 60287EAC 602879B0 60290B18 > 6023F2CC > > 6023F > > 2B8 I had the same error messages with a slave RSP card after hot swapping. On Ciscos recommendation they sent us a new one in 2 hours and everything worked fine again. > > > -- > > > Marc Teichtahl Manager, Data Network Engineering > Versa(tel Telecom NASDAQ: VRSA AEX: VERSA > > US Cell: +1 650 248 7058 Dutch Cell: +31 6 21213104 > -- Regards, Ulf. --------------------------------------------------------------------- Ulf Zimmermann, 1525 Pacific Ave., Alameda, CA-94501, #: 510-769-2936 Alameda Networks, Inc. | http://www.Alameda.net | Fax#: 510-521-5073
|