North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: 7507 debug error

  • From: Neil J. McRae
  • Date: Tue Jun 13 03:30:33 2000

> 
> HW problem, if you wasn't OIR'ing cards, I'd say you probably have a
> faulty card.
> 
> On Mon, Jun 12, 2000 at 10:38:35PM +0200, Marc Teichtahl wrote:
> > 
> > can anyone translate this for me ?
> > > Jun 12 21:41:07.679 CED: %RSP-3-RESTART: cbus complex
> > > Jun 12 21:41:55.996 CED: %DBUS-3-SW_NOTRDY: DBUS software not ready
> > after
> > > dbus_s
> > > lot_enable(), elapsed 12032, status 0x48
> > > -Traceback= 602A5284 602A6418 602B808C 60287EAC 602879B0 60290B18
> > 6023F2CC
> > > 6023F
> > > 2B8
> > > Jun 12 21:42:06.504 CED: %CBUS-3-CCBPTIMEOUT: CCB handover timed out,
> > CCB
> > > 0x5800
> > > FF20, slot 0
> > > -Traceback= 602BA350 602B7B98 602B8178 60287EAC 602879B0 60290B18
> > 6023F2CC
> > > 6023F
> > > 2B8
> > 
> > 
> > -- 
> > 
> > 
> > Marc Teichtahl				Manager, Data Network Engineering
> > Versa(tel Telecom			NASDAQ: VRSA AEX: VERSA
> > 
> > US Cell: +1 650 248 7058		Dutch Cell: +31 6 21213104
> > 
> > 
> 
> /Jesper
> 
> -- 
> Jesper Skriver, jesper(at)skriver(dot)dk  -  CCIE #5456
> Work:    Network manager @ AS3292 (Tele Danmark DataNetworks)
> Private: Geek            @ AS2109 (A much smaller network ;-)
> 
> One Unix to rule them all, One Resolver to find them,
> One IP to bring them all and in the zone to bind them.
> 
>