North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

RE: Majore North Jersey outage...

  • From: Alex Rubenstein
  • Date: Tue Nov 23 19:36:37 1999

It's a DACs upgrade that went awry.

It's been an interesting day.



On Tue, 23 Nov 1999, Charles Sprickman wrote:

> Was big?  IS big...  I watched all the BellAtlantic.net circuits into
> the ATM cloud come up while ours still languishes...  
> 
> Alex has the scoop, but I understand there's only 50% or so restored
> now.  No real good info from anyone on what the cause is.  They mumbled
> something about fiber and electricity on the support line, Northpoint said
> it was a botched upgrade...
> 
> Charles
> 
> On Tue, 23 Nov 1999, Martin, Christian wrote:
> 
> > 
> > Still feeling the effects -- this outage was big.  2000 (That's right, TWO
> > THOUSAND) DS3s were down for 12 hours or more.  Alcatel has been on-site for
> > 9 of them.
> > 
> > Chris
> > 
> > -----Original Message-----
> > From: Alex Rubenstein [mailto:[email protected]]
> > Sent: Tuesday, November 23, 1999 12:21 AM
> > To: [email protected]
> > Subject: Re: Majore North Jersey outage...
> > 
> > 
> > 
> > 
> > Just spoke to Bell Atl, major DACS failure in 'newark-2', aka 95 williams
> > st., newark.
> > 
> > 
> > 
> > On Tue, 23 Nov 1999, Alex Rubenstein wrote:
> > 
> > > 
> > > 
> > > Reports coming in from throughout the state show Fast Packet services
> > > (Frame, ATM), 411, 911, 0, 800, 900 services not working in much of north
> > > jersey (LATA 224).
> > > 
> > > Details to follow...
> > > 
> > > 
> > > 
> > 
> > 
> > 
> 
>