North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

Re: Frame Relay encap vis-a-vis point-to-point at UUNET (fwd)

  • From: Chris Whittenburg
  • Date: Fri Oct 23 17:51:55 1998
  • Uuencode: TRUE

> On Fri, Oct 23, 1998 at 11:48:00AM -0400, Eric Dean wrote:
> > You could also order a larger circuit with the same FR paramters.
> 
> The circuit in question is from UUNet.  We're not terribly interested
> in paying them more money when they are 3x more expensive than anyone
> else we get bandwidth from.
> 
> FWIW, Savvis does _not_ have this problem.
> 
> -- 
>  Jeffrey Haas   "He that breaks a thing to find out what it is has

What version of IOS are you running?  It could be this
cisco bug:

CSCdj91667: frame relay/serial: LMI or keepalives sent out of 
order/not sent.

regards,
chris