North American Network Operators Group

Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical

RE: OPS: SECURITY new packet of death

  • From: Darin Fisher
  • Date: Fri Nov 21 17:08:22 1997

Other vulnerabilities:

	Cisco PIX	NOT vulnerable
	Wellfleet	NOT vulnerable
	NPI EIFO	vulnerable (doesn't shut the system down, but
you can no longer monitor from telnet)
	IRIX 5.3		vulnerable
	IRIX 6.4		NOT vulnerable
	SunOS 4.1.3	vulnerable
	Solaris 2.4	NOT vulnerable
	Solaris 2.5.1 	NOT vulnerable
	Ultrix (all)	vulnerable
	HPUX 9.x	vulnerable
	HPUX 10.x	NOT vulnerable
	AIX 3.2.5	NOT vulnerable
	AIX 4.1		NOT vulnerable
	WinNT (w/ service pack 3)	a little vulnerable (slows the
system 'till SYN timeout)
	Win95 (w/ service pack 1)	NOT vulnerable (
	NCDware 3.3.2	vulnerable
	Linux	2.0.30	NOT vulnerable
	Novell 3.11	NOT vulneralbe
	Novell 3.12	NOT vulnerable
	Novell 4.10	NOT vulnerable
	Motorola SVR5 3.0	NOT vulnerable



> -----Original Message-----
> From:	Michael Behrens [SMTP:[email protected]]
> Sent:	Friday, November 21, 1997 12:51 PM
> To:	[email protected]
> Subject:	Re: OPS: SECURITY new packet of death
> 
> On Fri, 21 Nov 1997, Stan Barber wrote:
> 
> > BugTraq has a note that version 10.3(7) is vunerable. I don't know
> which
> > version of Cisco the IOS was running on.
> 
> version 11.1(5) is vulnerable.
> 
> Michael
> 
> |InterNet Kingston       #177 Wellington St. Ste #302|
> |Kingston, Ontario	 K7L3E3, Canada              |
> |http://www.kingston.net Bigger, Better, Local       |