North American Network Operators Group Date Prev | Date Next | Date Index | Thread Index | Author Index | Historical Re: Anyone Deployed Ascend's GRF IP Switch?
On Fri, 22 Aug 1997 10:20:50 -0700 [email protected] (Christofer Hoff) wrote: > SO, the bottom line...has anyone else deployed multiple GRF400's with > success. > Ascend will tell you that UUNET has deployed (or is going to) a > hundred or so. > I want to talk to people USING the technology, not thinking about it. > > Your comments and opinions are welcomed. > Yes I have a pile of them, they work well, but there are alot of gotchas on them. UUNET are using them now btw: >Trying 137.39.110.142... >Connected to 105.ga025.XR4.NYC1.Alter.Net. >Escape character is '^]'. > > >Ascend Embedded/OS 1.3 (XR4.NYC1.Alter.Net) (ttyp0) > >User: Connection closed by foreign host. And if you've not used gated before I'd recommend using PC's to do a mock up of your planned backbone. Regards, Neil. -- Neil J. McRae. Alive and Kicking. Domino: In the glow of the night. [email protected] NetBSD/sparc: 100% SpF (Solaris protection Factor) Free the daemon in your <A HREF="http://www.NetBSD.ORG/">computer!</A>
|