Re: FW: genieweb.com answering for COM

  • From: Michael
  • Date: Tue Jul 08 09:52:48 1997

>> >BIND 4.9.5-P1 and later (which is 4.9.6 and all versions of 8.*) is not
>> >susceptible to this corruption.  see ftp://ftp.isc.org/isc/bind/src.
>>
>> Two of the servers that I maintain were running BIND 4.9.5-P1 (now 8.1.1,
>> thanks isc) and were corrupted.
>
>i have not been able to reproduce this.  when reporting bugs, either here
>or to the [email protected] address, please provide a reproducable example.

Paul..

I apologize for this.. I really did want to get a dump of the database, but
my priorities lay in making my servers functional as soon as possible. I was
merely trying to inform you, as well as the others here who might be interested
that I had also seen the problem in 4.9.5-P1.

Thanks!

Michael